Using the mouse to select drag scope measurement cursors

88 ビュー (過去 30 日間)
Justin Mellor
Justin Mellor 2017 年 1 月 19 日
Using 2016b, I need to measure pulse timings from a standard Simulink scope. It does not seem to be possible to select and drag them using the mouse. The keyboard commands don't seem to work either.

採用された回答

Justin Mellor
Justin Mellor 2017 年 1 月 20 日
I will answer my own question...
What had not realized is that you need to deselect the pan/zoom button on the toolbar to allow you to select a cursor. I kept selecting the different options for this function using the drop-down arrow, but actually clicking on the icon allows it to be selected or deselected. Seems obvious now!
  8 件のコメント
Jon
Jon 2023 年 5 月 9 日
Came back to this same problem again. For future reference I note that to "deselect pan zoom" you may have to go to the "Tools" drop down on the scope and uncheck the offending zoom or pan selection.
SIRA E PALAZUELOS CAGIGAS
SIRA E PALAZUELOS CAGIGAS 2024 年 3 月 10 日
Thank you, it was useful!

サインインしてコメントする。

その他の回答 (2 件)

Jeremy Clavier
Jeremy Clavier 2017 年 4 月 27 日
Took time to understand for me also: hereby 2 pictures with selected and deselected pan. Only deslected pan will enable you to drag the cursors!

Jeffrey Smedley
Jeffrey Smedley 2021 年 12 月 20 日
I've just had the same problem. Thank you for posting your answer!

カテゴリ

Help Center および File ExchangeScopes and Data Logging についてさらに検索

タグ

製品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by