simscapepower and other block connection error

1 回表示 (過去 30 日間)
Yaser Arafat
Yaser Arafat 2016 年 11 月 24 日
コメント済み: Yaser Arafat 2016 年 11 月 29 日
I am trying to create a model using simscape but the unable to make connections between current measurement block to another block. I tried with Simulink ps converter but still having the same problem.For detailed understanding, I attached the image file

回答 (1 件)

Andrew Schenk
Andrew Schenk 2016 年 11 月 28 日
You cannot directly interface Simscape Power Systems Specialized Technology blocks with Simscape blocks. Consider replacing the Breaker block with the Simscape block https://www.mathworks.com/help/physmod/sps/ref/singlephasecircuitbreaker.html which will allow a direct connection.
Alternatively, use the following example to show how Specialized Technology blocks can be connected to Simscape blocks: https://www.mathworks.com/help/physmod/sps/powersys/ref/currentvoltagesimscapeinterface.html
  1 件のコメント
Yaser Arafat
Yaser Arafat 2016 年 11 月 29 日
Thank you, sir

サインインしてコメントする。

カテゴリ

Help Center および File ExchangeElectrical Sensors についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!