What is Block error in Simulink ?

13 ビュー (過去 30 日間)
Sathyanarayan Rao
Sathyanarayan Rao 2016 年 6 月 9 日
回答済み: Sabin 2023 年 3 月 18 日
I am trying to simulate a very simple RC circuit and I get the following error when I try to run the model.
Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the following blocks : AC Source, Resistor and Capacitor. I chose these components from Simscape Foundation library.

回答 (1 件)

Sabin
Sabin 2023 年 3 月 18 日
What you need is a Solver Configuration block for every physical network. This can be found in Simscape / Utilities.

カテゴリ

Help Center および File ExchangeCircuits and Systems についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!