Error in port widths or dimensions

2 ビュー (過去 30 日間)
yana osman
yana osman 2012 年 2 月 1 日
編集済み: Walter Roberson 2013 年 10 月 10 日
Hi everyone, I have a problem when running my simulink file. I have pid block and s-function block diagram in simulink file with the 11 outputs and 1 input. When I try to run this file I receive the following error for pid block:
Error in port widths or dimensions. Output port 1 of 'project1_simu/PID Controller' is a one dimensional vector with 11 elements
and the following error for s-function file:
Error in port widths or dimensions. Input port 1 of 'project1_simu/S-Function' is a one dimensional vector with 1 elements
How to solve this error?

採用された回答

Kaustubha Govind
Kaustubha Govind 2012 年 2 月 1 日
Apparently the S-function expects a scalar value, but you are feeding in a vector of length=11. If you've written the S-function, you need to use something like "ssSetInputPortWidth(S, 0, 11);" or "ssSetInputPortWidth(S, 0, DYNAMICALLY_SIZED);" in mdlInitializeSizes.
  2 件のコメント
yana osman
yana osman 2012 年 2 月 13 日
Thanks...but i received another error
" State derivatives returned by S-function 'chiu_sfcn' in 'project1_simu/S-Function1' during flag=1 call must be a real vector of length 11."
Do you have any ideas on how to solve this?
Kaustubha Govind
Kaustubha Govind 2012 年 2 月 13 日
The error clearly states the issue. The value you are returning for flag=1 needs to be a real vector of length=11. What are you returning in "sys"?