Simulink MPC Designer ZOH FOH Error
9 ビュー (過去 30 日間)
古いコメントを表示
I am trying to design an MPC controller using the simulink controller toolbox. Whenever I try to make the MPC sample time less that 1, I get the following error: "The "zoh" and "foh" methods cannot be used for discrete models with poles near z=0" Could someone please explain what the error means and how I fit my controller? Thanks
2 件のコメント
Jordan Olson
2020 年 7 月 1 日
I'm also having this issue, but changing the sample time in the MPC doesn't fix it.
回答 (1 件)
dekun wang
2021 年 5 月 18 日
poles in discrete domain near z=0 means poles in continuous domain tending to -infinite which means your system's natural frequency is infinitely large. It cannot be true for any systems. So my suggestion would be to double check your plant model.
0 件のコメント
参考
カテゴリ
Help Center および File Exchange で Model Predictive Control Toolbox についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!