Simulink MPC Designer ZOH FOH Error
古いコメントを表示
I am trying to design an MPC controller using the simulink controller toolbox. Whenever I try to make the MPC sample time less that 1, I get the following error: "The "zoh" and "foh" methods cannot be used for discrete models with poles near z=0" Could someone please explain what the error means and how I fit my controller? Thanks
2 件のコメント
Steven
2020 年 3 月 20 日
Did you ever fix this?
Jordan Olson
2020 年 7 月 1 日
I'm also having this issue, but changing the sample time in the MPC doesn't fix it.
回答 (1 件)
dekun wang
2021 年 5 月 18 日
0 投票
poles in discrete domain near z=0 means poles in continuous domain tending to -infinite which means your system's natural frequency is infinitely large. It cannot be true for any systems. So my suggestion would be to double check your plant model.
カテゴリ
ヘルプ センター および File Exchange で Controller Creation についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!