How do I fix rtiostream_serial_c28x.c?
古いコメントを表示
I am trying to run a very simple Simulink model in PIL mode. I get the following error.
"C:/MATLAB/SupportPackages/R2015b/texasinstrumentsc2000base/toolbox/target/supportpackages/tic2000_base/pil/+tic2000codertargetpil/../../src/rtiostream_serial_c28x.c", line 177: error: struct "SCIFFTX_BITS" has no field "TXFIFOXRESET".
Is there a problem with rtiostream_serial_c28x.c? or am I missing a setup parameter?
採用された回答
その他の回答 (1 件)
Sumith Sekharan
2016 年 6 月 7 日
1 投票
Hi John,
This issue is due to the difference in the register definition for SCIFFTX_BITS in TI ControlSUITE file F2837xS_sci.h. This register definition is changed after v160 of F2837xS ControlSUITE files (For example C:\ti\controlSUITE\device_support\F2837xS\v160). Issue is fixed in latest version of support package for R2016a.
Hope this helps. Thanks, Sumith
カテゴリ
ヘルプ センター および File Exchange で Texas Instruments C2000 Processors についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!