why type 2 FIR filter cannot be used to design high pass filter?
5 ビュー (過去 30 日間)
古いコメントを表示
can anybody explain why type 2 FIR filter cannot be used to design high pass filter?
0 件のコメント
回答 (1 件)
Honglei Chen
2016 年 1 月 14 日
This is because for Type II FIR, there is a zero corresponding to Nyqiust rate, i.e., half sampling frequency. However, a high pass filter needs to let that component pass, so it cannot be used for a high pass filter.
2 件のコメント
Honglei Chen
2016 年 1 月 14 日
You can think of the unit circle as the frequency axis. Starting from (1,0), which corresponds to the 0 frequency. If you travel along the circle and come back to the starting point, it corresponds to Fs. Therefore, half the circle is just Fs/2, which corresponds to z = -1. HTH