why type 2 FIR filter cannot be used to design high pass filter?

can anybody explain why type 2 FIR filter cannot be used to design high pass filter?

回答 (1 件)

Honglei Chen
Honglei Chen 2016 年 1 月 14 日

0 投票

This is because for Type II FIR, there is a zero corresponding to Nyqiust rate, i.e., half sampling frequency. However, a high pass filter needs to let that component pass, so it cannot be used for a high pass filter.

2 件のコメント

pavan sunder
pavan sunder 2016 年 1 月 14 日
how does Z=-1 corresponds to nyqiust frequency?
Honglei Chen
Honglei Chen 2016 年 1 月 14 日
You can think of the unit circle as the frequency axis. Starting from (1,0), which corresponds to the 0 frequency. If you travel along the circle and come back to the starting point, it corresponds to Fs. Therefore, half the circle is just Fs/2, which corresponds to z = -1. HTH

サインインしてコメントする。

カテゴリ

タグ

質問済み:

2016 年 1 月 14 日

コメント済み:

2016 年 1 月 14 日

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by