Simpowersystems Asynchronous Machine Inside Delta (6 wire) connection

1 回表示 (過去 30 日間)
McSpark
McSpark 2015 年 7 月 29 日
回答済み: Sebastian Castro 2015 年 7 月 29 日
Hello,
Is there a way to access all six stator winding connection points using this model to allow inside delta (6 wire) control?
Thanks

採用された回答

Sebastian Castro
Sebastian Castro 2015 年 7 月 29 日
I don't think there's an easy way for this.
If you look at the "Wound" configuration of the Asychronous Machine block, it exposes 6 physical connection ports -- 3 for the stator and 3 for the rotor.
You'd have to customize this block (using power_customize, for instance) and change the mathematical model such that the 6 voltages and currents correspond to the inside-delta connection points instead of the 3 stator and 3 rotor wye connections.
Alternatively, you could model the whole custom machine model using Simulink blocks. Either approach will require a modified mathematical model based on the existing Asynchronous Machine block.
I'd look at the power_SLmodeling example, or its documentation, as a starting point.
- Sebastian

その他の回答 (0 件)

カテゴリ

Help Center および File ExchangeElectrical Sensors についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by