Info
この質問は閉じられています。 編集または回答するには再度開いてください。
How can physical signal line can be connected with power system blocks?
2 ビュー (過去 30 日間)
古いコメントを表示
I have modeled some mathematical equations in simulink. i want to connect these with the sim power system blocks. Please suggest how it can be connected?
0 件のコメント
回答 (1 件)
Sebastian Castro
2015 年 7 月 16 日
編集済み: Sebastian Castro
2015 年 7 月 16 日
With the voltage/current source/sensor blocks in SimPowerSystems. You basically want to make sure your Simulink equations are of the form:
V = function(I) or I = function(V)
That way you can measure voltage, do the calculation, and apply a current back to the circuit -- or the opposite way if need be.
As a simple example, I'd point you to this page, which is the power_VariableInductor model. If you open up that model, right-click the "Variable Inductance" block and select "Mask > Look Under Mask" to see what I mean.
- Sebastian
3 件のコメント
Sebastian Castro
2015 年 7 月 17 日
Depends on how the models are made. If one is a SimPowerSystems model and the other is Simulink blocks, my original comment should hold.
Is there another thing you had in mind?
Huan Yu
2015 年 8 月 18 日
hello Mr. Sebastian,i wonder how to deal with the sim hydraulic blocks for the same purpose, pressure compensated pump for example.
この質問は閉じられています。
参考
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!