goto error when using more than one Single Phase Dynamic Load Block

hi I want to modeling IEEE 37 bus with simulink i want to modeling three phase unblanced constant current so i used Single Phase Dynamic Load Block but when I using more than one block i recive multipile goto error

1 件のコメント

Xinglei REN
Xinglei REN 2016 年 11 月 15 日
Could you share your Simulink model with me? I only want to use it evaluate my calculation. Thank you!

サインインしてコメントする。

 採用された回答

Sebastian Castro
Sebastian Castro 2015 年 6 月 9 日

2 投票

This problem no longer happens in the latest version (R2015a), but I tried on an older version and that was indeed the case.
Not sure how safe this is, but I could resolve the issue by right-clicking the block, selecting "Properties", going to the "Callbacks" tab, and deleting the text in the "CopyFcn" callback. Apparently that callback modifies the names of a Goto block in the Controlled Current Source inside the block, which causes a conflict when you have multiple of them dragged in.