How to solve the inertia error in Simscape Onramp Project ?
25 ビュー (過去 30 日間)
古いコメントを表示

2 件のコメント
Dyuman Joshi
2025 年 10 月 16 日 12:12
This problem has already been asked multiple times on MATLAB Answers.
I strongly suggest you go through the forum and see what the discussion there.
Also, Onramps provide solutions for problems in the assignment itself. You can refer that as well.
回答 (1 件)
Dyuman Joshi
2025 年 10 月 16 日 13:35
The error stems from the fact that there is an Electrical Reference which is connected to the Solver configuration.
Delete it and the model will pass the test.
3 件のコメント
Dyuman Joshi
2025 年 10 月 17 日 14:50
編集済み: Dyuman Joshi
2025 年 10 月 17 日 14:54
Ah, Idk how I picked the right thing but didn't convey it rightly. Anyways -
The negative connection from Rotational Electromechanical Converter should connect to the input of Controlled Voltage Source (negative), not the output (positive).