How to solve the inertia error in Simscape Onramp Project ?

25 ビュー (過去 30 日間)
Nour
Nour 2025 年 10 月 16 日 12:01
編集済み: Dyuman Joshi 2025 年 10 月 17 日 14:54
  2 件のコメント
Dyuman Joshi
Dyuman Joshi 2025 年 10 月 16 日 12:12
This problem has already been asked multiple times on MATLAB Answers.
I strongly suggest you go through the forum and see what the discussion there.
Also, Onramps provide solutions for problems in the assignment itself. You can refer that as well.
Nour
Nour 2025 年 10 月 16 日 12:19
I've already done that, but non of the answers were suitable to this error.
As for the solution provided by the training itself, it only included how to input the required paramaters.
Thank you though!

サインインしてコメントする。

回答 (1 件)

Dyuman Joshi
Dyuman Joshi 2025 年 10 月 16 日 13:35
The error stems from the fact that there is an Electrical Reference which is connected to the Solver configuration.
Delete it and the model will pass the test.
  3 件のコメント
Nour
Nour 2025 年 10 月 17 日 13:50
I tried what you said, but still the issue is not solved.
Dyuman Joshi
Dyuman Joshi 2025 年 10 月 17 日 14:50
編集済み: Dyuman Joshi 2025 年 10 月 17 日 14:54
Ah, Idk how I picked the right thing but didn't convey it rightly. Anyways -
The negative connection from Rotational Electromechanical Converter should connect to the input of Controlled Voltage Source (negative), not the output (positive).
See the attached image.

サインインしてコメントする。