Power Systems >ComponentsRepresent >Power Systems Components >(3/6) Synchronous>task 7
when I finsished everything in task 1 to 6 but at task 7 the problem my signal donsn't match the signal requirement
I dont know what I did wrong, I followed every instructions and complete it but this one is asking me to do a missing requirement that they never ask

0 件のコメント
採用された回答
Cris LaPierre
2024 年 12 月 20 日
You Synchronous Machine Salient Pole block does not look correct. You have 3 outputs on the right. You should only have 2. Specifically, the n port should not be showing.
It looks like you missed the 2nd item in Task 1. Zero sequence should be set to Exclude. It appears this is not assessed so wasn't caught earlier. Make this change and your model should pass.