フィルターのクリア

adaptive model predictive control

1 回表示 (過去 30 日間)
E U
E U 2015 年 5 月 17 日
コメント済み: E U 2015 年 5 月 19 日
In the following link (or above picture) in the controlled system, why are the initial inputs and outputs are subtracted from system inputs/outputs and the resulting signals then delayed? I have indicated these parts in a red rectangle.

採用された回答

Arkadiy Turevskiy
Arkadiy Turevskiy 2015 年 5 月 18 日
The intitial values are substracted to remove the offset from the data. The delay block resamples continuous signals coming from the plant model, as the estimator requires discrete-time signals sampled at Ts. You could use Rate Transition block instead.
Hope this helps.
  1 件のコメント
E U
E U 2015 年 5 月 19 日
Thanks Arkadiy for your answer. Still, I wonder the question that I asked in the attached picture. I will be happy for your feedback on my question.

サインインしてコメントする。