Synchronous machine in simscape specialized power system with isolated starpoint !

35 ビュー (過去 30 日間)
Friedrich Schmidt
Friedrich Schmidt 2024 年 11 月 11 日 23:25
コメント済み: Friedrich Schmidt 2024 年 11 月 15 日 14:35
In MATLAB Simscape specialized power system the synchronous machines comes with the three-phase supply without any neutral point pin outside. In the description of the block it is mentioned about internal neutral point. Is there any way to get a isolated starpoint instead ?

回答 (2 件)

Swastik Sarkar
Swastik Sarkar 2024 年 11 月 12 日 5:16
While reviewing the Simplified Synchronous Machine documentation, it was found that the neutral wire can be exposed by setting the parameter Connection Type to 4. More details about this can be found here:
Hope this helps !

Friedrich Schmidt
Friedrich Schmidt 2024 年 11 月 12 日 12:25
Hi Swastik, Thanks a lot for your answer! :-) I use not the simplified models but the full featured models synchronous machine pu standard synchronous machine pu or si fundamental Friedrich
  2 件のコメント
Swastik Sarkar
Swastik Sarkar 2024 年 11 月 13 日 4:27
I had gone through their documentation too, but I did not find the mention of "internal neutral point" in the description of the block, could you please link the part which specifies this ?
Friedrich Schmidt
Friedrich Schmidt 2024 年 11 月 15 日 14:35
Hello Swastik!
Thank you for your answer and sorry for my late reply. You can see the information for the neutral point in the parameter dialog for the synchronous machine block ( first two lines above ) !
Regards,
Friedrich

サインインしてコメントする。

カテゴリ

Help Center および File ExchangeChoose and Parameterize Blocks についてさらに検索

製品


リリース

R2023a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by