フィルターのクリア

How can I log signals in referenced models while running rapid accelerator?

2 ビュー (過去 30 日間)
Paul
Paul 2011 年 1 月 21 日
Is it possible to log signals in referenced models in Simulink when the simulation is running under rapid accelerator? As far as I can tell, it's not possible. Am I missing something?

採用された回答

MarkB
MarkB 2011 年 1 月 21 日
Unfortunately, there is currently (as of R2010b) a limitation in Simulink that prevents logging signals in accelerated models. There are some "rough" alternatives, such as using "ToWorkspace" and "ToFile" blocks that might let you at least capture the data that interests you, but it is not as convenient as signal-logging would be.
  2 件のコメント
Paul
Paul 2011 年 1 月 21 日
ToWorkspace blocks are inoperable in referenced models. A ToFile block would work as long as there is only one instantiation, and I'm sure it would slow things down quite a bit. Hopefully this problem is high up on the enhancements list?
Paul
Paul 2011 年 1 月 21 日
Also, just to clarify: signal logging works in accelerated models, but not in rapidly accelerated models.

サインインしてコメントする。

その他の回答 (0 件)

カテゴリ

Help Center および File ExchangePrepare Model Inputs and Outputs についてさらに検索

製品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by