Adsorption process in Simulink

12 ビュー (過去 30 日間)
Ababacar Thiam
Ababacar Thiam 2024 年 10 月 1 日
コメント済み: Ababacar Thiam 2024 年 10 月 8 日
How to create a switch command between adsorption and desorption in Simulink?
  2 件のコメント
Rahul
Rahul 2024 年 10 月 4 日
Hey @Ababacar Thiam, can you share your Simulink Model, or describe your use case, that'll help in better understanding the isssue.
Ababacar Thiam
Ababacar Thiam 2024 年 10 月 4 日
Thanks for your answer Rahul. We first simulated adsorption in one block. Then we simulated desorption in another block. We seek to regroup the two blocks so as to have the desorption-adsorption sequence.

サインインしてコメントする。

採用された回答

Altaïr
Altaïr 2024 年 10 月 8 日
To switch between the two subsystems (adsorption and desorption) based on a control signal, the ‘Switch block can be used. The control signal can be generated in a couple of ways:
  1. Using ‘Relational Operator’ and ‘Logical Operator’ blocks if the switching logic is simple.
  2. For more complex switching logics, a ‘Stateflow’ chart can be used.
You can learn more about the Switch block in the following documentation page.
Here’s an example for the Switch’ block that outputs the absolute value of a biased sine wave. The below model switches between ‘subsystem1’ and ‘subsystem2’ depending on the value of ‘controlSignal.
The output seen in the scope would be as follows:
You can refer to the attached model for further assistance. To switch between several subsystems, the ‘Multiport Switch’ block can be used. Feel free to check out the following documentation page.
I believe this will assist you!
  1 件のコメント
Ababacar Thiam
Ababacar Thiam 2024 年 10 月 8 日
Thanks a lot Ashok, I will try to the simulation with your explications

サインインしてコメントする。