Sample time mismatch between IF block and Action Port in Action Subsystem.
6 ビュー (過去 30 日間)
古いコメントを表示
Hello everyone,
I wanted to encrypt the subsystems of a model, to do that I added the unit delay(to break algebric loop) and tried to convert to model reference. But am receiving this error - 'Sample time [0, 1] of '.../If Action Subsystem/Action Port' does not match the discrete sample time of the If block '.../If' controlling its execution.' I am getting this error after adding the unit delay block, the IF block is present in one of the subsystems. Is there any other way to encrypt or is there any way I can solve this sample time issue.
Please explain in simple terms as I am relatively new to simulink.
Thanks in advance,
DV
4 件のコメント
Malay Agarwal
2024 年 9 月 25 日
編集済み: Malay Agarwal
2024 年 9 月 25 日
The model seems to be missing some files and variables requires to run it. Could you add those files, variables?
Francisco J. Triveno Vargas
2024 年 10 月 9 日
HI,
Initially, try to change to fixed step and select one Sample Time.
回答 (1 件)
Jaimin
2024 年 12 月 24 日
Hi @Dhrupad
The error you are experiencing is due to a discrepancy in sample times between the “If” block and the “Action Port” within the “If Action” Subsystem. This usually occurs when the “If” block has a discrete sample time, but the Action Subsystem anticipates a different sample time.
Steps to Resolve the Sample Time Issue
Check Sample Times:
- Open the “If” block and check its sample time settings.
- Ensure that the sample time of the If block matches the sample time of the Action Subsystem.
Adjust Sample Times:
- Set the sample time of the “Action” Subsystem to match the “If” block's sample time.
- Alternatively, you can set both to inherit the sample time by using “-1” (which means they will inherit the sample time from the parent system).
Use Rate Transition Blocks:
- If you need to manage different sample times, consider using a Rate Transition block to handle the transition between different sample rates.
Model Reference Conversion:
- When converting to a model reference, ensure that all blocks within the subsystem have compatible sample times and that any algebraic loops are properly broken.
For more information kindly refer following MathWorks documentation.
I hope this will be helpful.
0 件のコメント
参考
カテゴリ
Help Center および File Exchange で Subsystems についてさらに検索
製品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!