How to label a signal using a sub-system mask parameter in Simulink?

24 ビュー (過去 30 日間)
Kevin
Kevin 2024 年 9 月 5 日
コメント済み: Kevin 2024 年 9 月 6 日
Hello!
I am working in Simulink and I have a masked subsystem with a string mask parameter. Within the subsystem I want to label a signal based in this parameter. How can I go about doing this? Thank you in advance.

採用された回答

Abhishek Kumar Singh
Abhishek Kumar Singh 2024 年 9 月 6 日
編集済み: Abhishek Kumar Singh 2024 年 9 月 6 日
Hi @Kevin,
I found a method to dynamically rename signal labels using mask parameters in Simulink:
Firstly retrieve Mask Parametes:
sigLabel = get_param('your_model/Subsystem', 'myParam');
Assuming myParam is the parameter name.
Then get all the port handles from a certain block/subsystem inside of your subsystem mask:
PortHandles = get_param('your_model/Subsystem/block1', 'PortHandles');
Use getfullname to identify the index of output port you want to rename. Then rename the signal:
set_param(PortHandles.Outport(1), 'Name', sigLabel);
Replace 1 with the index of outport of your choice. This approach allows you to update the signal name based on a mask parameter, enhancing flexibility in your model. Adjust 'your_model/Subsystem', 'block1' and 'myParam' to fit your specific model, block and parameter names.
You can further add this code to PostLoadFcn or InitFcn callback to automate this. Refer to the doc here: Model Callbacks - MATLAB & Simulink (mathworks.com)
Hope this helps.
  3 件のコメント
Abhishek Kumar Singh
Abhishek Kumar Singh 2024 年 9 月 6 日
Hi @Kevin,
It is working but you are not able to see the results as you are getting port handle of the subsystem and no signal is emanating from there. Try connecting a Terminator and it works:
If you want to rename the signal inside of the subsystem, you will need to get corresponding port handle:
portHandles = get_param('test_signallabeling/mainSub/Add', 'PortHandles')
Reg. your query related to port handles, indeed they are double- as expected. To get the name, use getfullname function:
getfullname(portHandles.Outport)
Kevin
Kevin 2024 年 9 月 6 日
This worked, thank you for your help!

サインインしてコメントする。

その他の回答 (1 件)

Paul
Paul 2024 年 9 月 6 日
Hi Kevin,
I was able to change a signal name in the masked subsystem using code in the mask initialization code. In my simple example, I have a masked subsystem with a dialog parameter called sname.
The first line of code gets the handles to the ports of the Gain block. The second line changes the name of the signal output from the Gain block to the string value in the mask dialog for the sname parameter.
ph = get_param([gcb,'/Gain'],'PortHandles');
set_param(ph.Outport,'Name',sname)
I think you should be able to adopt this to your model.