how to model a varying load in Simulink using specialized power system library in single phase
35 ビュー (過去 30 日間)
古いコメントを表示
Hello, I'm modelling a Full-Active Hybrid Energy Storage System in Simulink using specialized power system library, For getting proper results, i need a varying load. The varying load prsent in this library is in 3-phase.. I need a single phase varying load. Can anyone help?
0 件のコメント
採用された回答
Sayan
2024 年 5 月 30 日
Hi Irfan,
One way of doing this is by creating your own Single-phase varying load. To do this you can use the "Variable Resistor" , "Variable Capacitor" and "Variable inductor" and rearrange them to connect them in parallel or series. You use signal blocks from Simulink > Sources to control the impedence values.
You can refer this following example where a "Variable inductor" is used.
If you need to use a "Single Phase Dynamic Load" you can refer to the following example and reuse the custom built block in your model.
Hope this answers your query.
その他の回答 (0 件)
参考
カテゴリ
Help Center および File Exchange で Physical Units についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!