how to model a varying load in Simulink using specialized power system library in single phase

Hello, I'm modelling a Full-Active Hybrid Energy Storage System in Simulink using specialized power system library, For getting proper results, i need a varying load. The varying load prsent in this library is in 3-phase.. I need a single phase varying load. Can anyone help?

 採用された回答

Sayan
Sayan 2024 年 5 月 30 日
Hi Irfan,
One way of doing this is by creating your own Single-phase varying load. To do this you can use the "Variable Resistor" , "Variable Capacitor" and "Variable inductor" and rearrange them to connect them in parallel or series. You use signal blocks from Simulink > Sources to control the impedence values.
You can refer this following example where a "Variable inductor" is used.
If you need to use a "Single Phase Dynamic Load" you can refer to the following example and reuse the custom built block in your model.
Hope this answers your query.

1 件のコメント

Thank you, i used the single phase dynamic block and it worked perfectly.