variable duty ratio to a switch at different time intervals
5 ビュー (過去 30 日間)
古いコメントを表示
KESARI HANUMANTHU
2024 年 4 月 12 日
コメント済み: Manikanta Aditya
2024 年 4 月 13 日
I want to supply a gate pulse to an IGBT switch in DC-DC converter with a duty ratio of 40% from 0 to 2 seconds and 2 to 4 seconds with simulation time of 6 seconds and i want to disconnect the gate pulse to switch from 4 to 6 seconds. how to do this in simulink. The switching frequency of IGBT switch is 20 kHZ.
6 件のコメント
Fangjun Jiang
2024 年 4 月 12 日
@Manikanta Aditya, which Pulse Generator block are you referring to? I didn't find the place to "Define Variable Duty Ratio in Pulse Type Attributes".
Manikanta Aditya
2024 年 4 月 13 日
I meant the Pulse Generator block in Simulink that allows defining a variable duty ratio based on time.
採用された回答
Fangjun Jiang
2024 年 4 月 12 日
I assume this is in Simulink. You can use an AND logic block or Product block to multiply two signals. One is the regular 40% duty cycle PWM all the time, the other is this On/Off signal based on pre-determined timing or based on event by other Simulink signal.
3 件のコメント
Fangjun Jiang
2024 年 4 月 12 日
You could use a Signal Builder block. Or use a Switch block, before t<4, pass the PWM. After that, switch to 0.
その他の回答 (0 件)
参考
カテゴリ
Help Center および File Exchange で Electrical Block Libraries についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!