フィルターのクリア

Difficulty Generating Analog Output of White noise - Data Acquisition Using Simulink NI USB-6009

1 回表示 (過去 30 日間)
RAJA KUMAR
RAJA KUMAR 2023 年 12 月 19 日
コメント済み: RAJA KUMAR 2023 年 12 月 20 日
I am facing challenges in generating the analog output of a white noise using Simulink in conjunction with the NI USB-6009 data acquisition device. Despite my efforts to configure the system appropriately, I have been unable to achieve the desired output.
  2 件のコメント
Rik
Rik 2023 年 12 月 19 日
Have a read here and here. It will greatly improve your chances of getting an answer.
Your question is not urgent, the reason for that is explained here.
Walter Roberson
Walter Roberson 2023 年 12 月 19 日
@RAJA KUMAR comments to @Rik
I appreciate your generous suggestions. Can you suggest some solution to the problem?

サインインしてコメントする。

回答 (1 件)

Walter Roberson
Walter Roberson 2023 年 12 月 19 日
If the bounded option is enabled, the output is uniform white noise with amplitude between +1 and −1. If the bounded output is not enabled, the output is a Gaussian white noise and the values are not bounded between +1 and −1
Values that are in the range -1 to +1 are generally not in the range 0 to +5 as is expected for the way you have configured the output block.
  1 件のコメント
RAJA KUMAR
RAJA KUMAR 2023 年 12 月 20 日
Dear sir,
After applying your suggestions, I am still getting the same error. I have attached the figure

サインインしてコメントする。