Type Simulink.m​etamodel.f​oundation.​ValueType issue with Autosar System Composer architecture.

20 ビュー (過去 30 日間)
I'm using Simulink 22b system composer for Autosar architecture.
When trying a model update I get this error:
Type Simulink.metamodel.foundation.ValueType of property Type on [noname] doesn't match type Simulink.metamodel.types.ConstantSpecification of value [noname]
What could be the source of it, and how could I possibly fix it? I can't find anything on Simulink.metamodel.

採用された回答

Chaitanya Krishna Kantambhatla
Chaitanya Krishna Kantambhatla 2023 年 11 月 14 日
Hello Gergely,
I understand that you are receiving the error while updating an AUTOSAR model in Simulink R2022b.
I would like to let you know that this is a known bug and I apologize for this experience. The fix for the same is released in R2022b Update 6, R2023a Update 3 as well as R2023b. Please update the MATLAB to any of the above version to resolve the issue.
I hope this helps.

その他の回答 (0 件)