- Open-Circuit Voltage for Zero Sequence: you'll need to perform a simulation or measurement under zero sequence conditions. You can apply a zero sequence voltage at the motor terminals while keeping the other phases open-circuited. Measure the resulting voltage across the motor terminals.
- Short-Circuit Current for Zero Sequence: Similarly, you'll need to simulate or measure the short-circuit current under zero sequence conditions. This involves applying a short circuit to the motor terminals while injecting a zero sequence current. Measure the resulting current.
how to calculate Zero Sequence inductance(L0)For IPMSM delta connection
14 ビュー (過去 30 日間)
古いコメントを表示
I have Ld,Lq values for IPMSM delta connection.These Ld,Lq values were taken from motor cad.But Motor cad could not provided Zero Sequence inductance(L0).So,I want to know how to calculate Zero sequence inductance(L0) for ipmsm delta connection.
0 件のコメント
採用された回答
Mohamad Nazir
2023 年 8 月 28 日
The zero sequence inductance can be calculated using L0 = V0open/I0short where V0open is the open-circuit voltage for the zero sequence and I0short is the short-circuit current for the zero sequence.
Hope this helps
0 件のコメント
その他の回答 (0 件)
コミュニティ
その他の回答 パワー エレクトロニクス コミュニティ
参考
カテゴリ
Help Center および File Exchange で Simscape Electrical についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!