unable to resolve cooling plate error

4 ビュー (過去 30 日間)
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT 2023 年 7 月 26 日
回答済み: Joel Van Sickel 2023 年 7 月 28 日
hi there,
i am modelling a battery module with cooling plate. while running the simulation, i am getting this error;
"Error compiling Simscape network for model molicell_module_with_cooling_plate.
Caused by:
Connection 'connect(NewModule.BottomExtClnt,Parallel_Channels.Side1)' is found to be connecting arrays of nodes of inconsistent sizes: '1x14' and '1x196'. The arguments in a connection must be of the same size."
kindly help in resolving this error. Thanks
  3 件のコメント
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT 2023 年 7 月 26 日
Thanks for responding sir. I have used battery builder app to build the battery module with 14X14 cylindrical cells. ambient coolant path and coolant thermal path are set to " cell based internal resistance". i have attached the model along with cooling plate parameters.i am not sure if the parameters of cooling plate matching with nodes of battery module? please help.
Hyunwoo
Hyunwoo 2023 年 7 月 27 日
I have the same problem, did you solve it?

サインインしてコメントする。

採用された回答

Joel Van Sickel
Joel Van Sickel 2023 年 7 月 28 日
I think you need to set your number of nodes to 14 and not 14x14 for the cooling plate. If that doesn't solve it, please share your model instead of screen shots to get further assistance.