Getting 'empty' Compiled Port Data Types
24 ビュー (過去 30 日間)
古いコメントを表示
I'm trying to write a script to get datatypes of an inport and a outport of a subsytem/block. When I run following command:
get_param(port_handle,'CompiledPortDataType')
an empty array/structure is returned. Model is compiled before running this command. 'CompiledPortDataDimensions' also returns an empty results.
1 件のコメント
Paul
2023 年 7 月 4 日
If you do get this sorted out, please post the solution either here and/or in the linked question.
採用された回答
Andy Bartlett
2023 年 7 月 7 日
編集済み: Andy Bartlett
2023 年 7 月 7 日
Set model in compile mode to access data types
This may be changing, but historically at least, compiled port data types are available only when the model is actively in compiled mode.
mdl = 'fxpdemo_feedback';
open_system(mdl)
% "Lock" model in compiled mode
%
% NOTE: you will not be able to edit or even close model
% until compiled mode is terminated !!!
%
% TIP: Use try catch to avoid being unwittingly stuck in compile mode
%
try
eval([mdl,'([],[],[],''compile'')']);
blk1 = 'fxpdemo_feedback/A2D';
pdt1 = get_param(blk1,'CompiledPortDataTypes');
blk2 = 'fxpdemo_feedback/Controller/Combine Terms';
pdt2 = get_param(blk2,'CompiledPortDataTypes');
catch
end
eval([mdl,'([],[],[],''term'')']);
pdt1, pdt2
3 件のコメント
Andy Bartlett
2023 年 7 月 7 日
1) Yes, there is definitely a more modern syntax to get into compiled mode that what I should. The command you gave looks correct (but I didn't test it).
2) Yes, "must be in compiled mode" is more correct / clearer IMHO.
3) Yes, when stopped in the Simulink debugger, the model should still be "in compiled mode."
Paul
2023 年 7 月 8 日
Hi Andy,
Thanks for the response. It turns out that this command
set_param(gcs,'SimulationCommand','compile');
results in an error.
Do you know if there is a doc page that discusses all of the valid setting for SimulationCommand? I can only find example uses, but not a complete list.
その他の回答 (1 件)
VBBV
2023 年 7 月 3 日
編集済み: VBBV
2023 年 7 月 3 日
Run the model once (insted of just compiling) and check if model generates any data from ports and call or run the command
get_param(port_handle,'CompiledPortDataType')
Possibly no data might have been generated by model
4 件のコメント
VBBV
2023 年 7 月 4 日
編集済み: VBBV
2023 年 7 月 4 日
Ok. Test your model with valid inputs or input range. Before running your model, check simulation settings also e.g. time scale for simulation etc. A reasonable time duration. If the same problem exists then verify for any model inconsistencies.
BTW , how is the data being read from I/O ports ? Do you use read or some other functions to read data from ports ?