I can't connect a load component to the signal source
3 ビュー (過去 30 日間)
古いコメントを表示
i want to connect between "constant power load" component to "signal generator" component, the line just not conect and the end of line that exit from "constant power load" component is a circle and the end of line that exit from"signal generator" component is aמ arrow, as you see here:
what is the problem?
how can i fix it?
thenks.
0 件のコメント
採用された回答
Nikhil Baishkiyar
2023 年 6 月 15 日
The signal generator block belongs to Simulink while the Constant Power Load belongs to Simscape. They belong to different modelling environments (you can see that the color of blocks are different) and cannot be connected together directly.
You must use a Simulink-PS converter to interface Simscape with Simulink and PS-Simulink converter to interface Simulink with Simscape.
2 件のコメント
Nikhil Baishkiyar
2023 年 6 月 15 日
編集済み: Nikhil Baishkiyar
2023 年 6 月 15 日
I assume you want to make something like this