Simulink Missing Reference Error
9 ビュー (過去 30 日間)
古いコメントを表示
Hello, I'm not a novice at MATLAB but I am at simulink, and my code keeps claiming that its missing a reference, when i DO have a reference. I'm wondering if someone could shed some light on the subject.
Here's the error: Number of variables exceeds number of equations. Check for missing reference node.
From what I've ready you need a solver block for each domain, and i should only have one electrical domain. I've tried removing parts till it works but so far this is as smiple as i could make it without destroying the idea I'm trying to simulate.
Thanks! Dustin
0 件のコメント
採用された回答
Guy Rouleau
2011 年 10 月 29 日
The Controlled PWM voltage block is sort of special. The 2 sides are independent, so you must have a ground on each side.
Add a ground on the side where you only have a source.
I recommend contacting technical support with your model to request a more relevant error message.
その他の回答 (0 件)