Discrete Average on Simulink

Hi, I have a problem in Simulink. I should obtain the average value of a signal but I should keep this average value for the next 600 steps time. During these steps the output value is constant and it has to be updated each 600 new steps. How can I do this? Thank you so much.

4 件のコメント

Paul
Paul 2023 年 2 月 23 日
Some clarification is needed.
For sake of discussion, let's assum that each step is 1 second.
For t < 600, the output should be 0?
For 600 <= t < 1200, the output should be held at the average value over 0 <= t <= 600?
What should the output be from 1200 <= t < 1800? This is the key question?
Then for 1800 <= t < 2400 the output should be held at the average value of over 1200 <= t <= 1800. Correct?
Marco Minneci
Marco Minneci 2023 年 2 月 23 日
Yes, you understood. If possible I would like also an initial condition.
Paul
Paul 2023 年 2 月 23 日
What should the output be from 1200 <= t < 1800?
Marco Minneci
Marco Minneci 2023 年 2 月 23 日
The output from 1200 to 1800 should be the average of the input from 600 to 1200. The key question is how can I obtain this in simulink.

サインインしてコメントする。

回答 (2 件)

Fangjun Jiang
Fangjun Jiang 2023 年 2 月 23 日
編集済み: Fangjun Jiang 2023 年 2 月 23 日

2 投票

See attachment. Use "window length" of "6" instead of "600" to illustrate.
The build-in "Moving Average" block (it requires "DSP System Toolbox") seems like the right one to use. Need to debug further to see why the "initial condition" of the "Rate Transition" block (It behaves as a zero-order hold block) didn't take effect.
I also tried to use a MATLAB Function block to implement this. It is not too hard as long as you have a clear mind of the logic.
"InitialValue" and "WindowLength" is set in base workspace using the model PreLoadFcn callback.

2 件のコメント

Marco Minneci
Marco Minneci 2023 年 2 月 23 日
Ok, Perfect. It works. Thank you so much!!
Marco Minneci
Marco Minneci 2023 年 4 月 20 日
Hi, I have another problem on the same topic. I would know if it is possible to have this particular structure but with a variable step size (the size for the solver of simulink). Thank you in advance.

サインインしてコメントする。

Paul
Paul 2023 年 2 月 23 日
編集済み: Paul 2023 年 2 月 23 日

0 投票

If I understand the question correctly .....
Use a Discrete FIR Filter block to maintain a running average of 600 samples. Set the Sample Time parameter to the desired value or leave as -1 for inherited if the input signal is already at the desired sample time.