how to find integral and proportional constants.how can i interface it with a PWM and switch input to get desired op.
3 件のコメント
Sam Chak
2022 年 9 月 3 日
Could you provide the transfer function of the boost converter? It helps to determine the suitable values for the PI gains.
採用された回答
Joel Van Sickel
2022 年 9 月 6 日
Hello,
please use the references on this page to dive deeper into designing closed loop control for boost converters.
Regards,
Joel
0 件のコメント
その他の回答 (1 件)
Pranav Pillai
2022 年 9 月 9 日
1 件のコメント
Joel Van Sickel
2022 年 9 月 9 日
Hello Pranav, if you use average mode converter models, you can do it fairly simply using the controls toolboxed and the model linearizer app.
If you want to keep switching involved, you'll need to do a frequency reponse
Here is the basics for frequency response estimation.
One other alternative is since it's a boost converter, you can derive the 2nd order transfer function of the system, and close the loop with your PI controller using matlab commands or do it analytically. Wikipedia has the equivalent closed loop system for controller and plant defined as transfer functions available publicly, but getting the 2nd order transfer function for a boost converter is mostly in conference and journal papers.