Defining pmsm parameters for delta configuration
5 ビュー (過去 30 日間)
古いコメントを表示
I am trying to define the parameters for a PMSM in delta configuration in SimScape. By considering the layout diagram for the wye wound configuration in the help window related to the block I can see that the phase-phase terminal resistance and inductance specified on the datasheet should be divided by 2 to define the 'per phase' resistance and axis inductances for the pmsm.
I am not so clear on defining these parameters for a delta wound configuration as there is no layout diagram for this, does the winding configuration influence how these parameters are defined? From looking at other delta wound layout diagrams I would be leaning towards not dividing these parameters by 2.
0 件のコメント
回答 (1 件)
Dr Narayanaswamy P R Iyer
2022 年 6 月 6 日
The resistance and inductance values must be multiplied by 2/3 to get the per phase values for delta configuration. Thanks. DR. N P R IYER.
0 件のコメント
コミュニティ
その他の回答 パワー エレクトロニクス コミュニティ
参考
カテゴリ
Help Center および File Exchange で Choose and Parameterize Blocks についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!