Scope in Simulink does not display waveform correctly

Hello!
In Simulink I implement a very simple circuit with an AC voltage source (110kV,50Hz) in series with a Resistance R=1 Ohm and PowerGUI set to Discrete (Ts=5e-5s). I use also a "voltage measurement" block and a Scope to display the voltage waveform of the source. When I set the "Stop simulation time" to 0.2s the waveform is displayed from 0 to 0.2s as it was expected but when I set it to 0.4s it starts from around 0.15s (???). The same behavior occurs when I just use "Sine wave function" block with a Scope. There is something wrong with the scope because when I plot through the workspace everything is ok.
I would be grateful if somebody has a solution on this issue and could share it!
Regards, Michail

 採用された回答

Azzi Abdelmalek
Azzi Abdelmalek 2014 年 12 月 2 日
編集済み: Azzi Abdelmalek 2014 年 12 月 2 日

3 投票

I suppose your sample time is very small, in the scope parameters-history uncheck limit data point to last

2 件のコメント

Michail
Michail 2014 年 12 月 2 日
Perfectly right! Thank you very much for your help!
Amira benAmeur
Amira benAmeur 2017 年 8 月 10 日
Thank you for your help!

サインインしてコメントする。

その他の回答 (1 件)

Alireza Babaloo
Alireza Babaloo 2016 年 2 月 3 日

0 投票

I had the same problem thanks.

製品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by