for simulation of pid controller what should I use N filter coefficient value 1 or 100?
    10 ビュー (過去 30 日間)
  
       古いコメントを表示
    
for simulation of pid controller what should I use N filter coefficient value 1 or 100?
Im tuning PID Controller for buck converter voltage regulation, can I use N value 1 or 100? or 1000? 5000?
0 件のコメント
回答 (1 件)
  Sam Chak
      
      
 2022 年 9 月 5 日
        I don't know your Buck Converter model. However, in this example, the filter divisor N is 751. Generally, the value for N is high. Since you asked about the value for N, then I guess you designed yours using the ideal form:
If your theoretical ideal 
 gives a good performance on paper, then you should make this term 
 in the denominator of the derivative filter relatively small, 
 because

% Buck Converter Transfer Function
V  = 100;
C  = 1e-6;
L  = 2.2e-3;
R  = 500;
Gp = tf(V/(C*L), [1 1/(R*C) 1/(C*L)])
margin(Gp)      % Stable but Phase margin is very small, oscillatory response is expected
step(Gp)        % as confirmed by the step response
% standard-form PID with 1st-order derivative filter
Kp = 0.03;          % proportional gain
Ti = 3.6e-6;        % integral time
Td = 0.0006;        % derivative time
N  = 751;           % filter divisor
Gc = pidstd(Kp, Ti, Td, N)
margin(Gc*Gp)       % Phase margin is improved to approximately 60 deg
% closed-loop system and check if no RHP poles
Gcl = zpk(feedback(Gc*Gp, 1))
tau = 4e-5;
[u, t] = gensig('square', tau, 2*tau, tau/2^10);
lsim(Gcl, u, t), ylim([-1 2]), grid on
S = stepinfo(Gcl)