Type mismatch for equation
14 ビュー (過去 30 日間)
古いコメントを表示
Error compiling Simscape network for model RobotAssembly.
Caused by:
['RobotAssembly/PS Integrator']: Type mismatch for equation. The left hand side of the equation is {[1x1 double], '1/s'} and the right hand side of the equation is [1x1 double]. In foundation.signal.linear.integrator (line 59)
x = [1x1 double]
I = [1x1 double]
Component: Simulink | Category: Model error
And the code in integrator.ssc file is as below:
component integrator
% PS Integrator :0.75 :fixed
% This block performs continuous-time integration of the input Physical Signal.
% The output resets to the initial condition when the optional reset signal, R,
% triggers. The initial condition can be a fixed parameter or defined via
% physical signal, X0.
% Copyright 2019-2020 The MathWorks, Inc.
inputs
I; % :left
end
outputs
O; % :right
end
inputs(ExternalAccess=none)
R; % R:left
X0; % X0:left
end
parameters
reset_method = foundation.enum.IntegratorResetSpec.None; % External reset
initial_condition_spec = foundation.enum.IntegratorICSpec.Internal; % Initial condition source
end
parameters(ExternalAccess=none)
x0 = { 0, 's' }; % Initial condition
end
if initial_condition_spec == foundation.enum.IntegratorICSpec.Internal % Parameterized initial condition
annotations
x0 : ExternalAccess=modify;
end
parameters
IC = x0;
end
variables(Access = private)
x = {value = x0.*ones(size(I)), priority = priority.high};
end
else % Physical signal initial condition
annotations
X0: ExternalAccess=modify;
end
intermediates(ExternalAccess=none)
IC = X0;
end
outputs(Access = private)
x
end
equations(Initial=true)
x == IC.*ones(size(I));
end
end
if reset_method == foundation.enum.IntegratorResetSpec.None % No reset
equations
x.der == I;
end
else
annotations
R : ExternalAccess=modify;
end
outputs(Access = private, ExternalAccess=none)
y
end
% Declare reset event variable
variables(ExternalAccess = none, Event = true)
reset = {value = 0, priority = priority.high};
end
% Set criteria for reset
if reset_method == foundation.enum.IntegratorResetSpec.Either % Rising or falling edges
events
when edge(R>0) || edge(R<0) || edge(R==0)
reset = 1
elsewhen edge(reset) % Immediately put reset back to 0
reset = 0;
end
end
else
if reset_method == foundation.enum.IntegratorResetSpec.Rising % Rising edge
intermediates(ExternalAccess=none)
reset_condition = R>0;
end
else % Falling edge
intermediates(ExternalAccess=none)
reset_condition = R<=0;
end
end
events
when edge(reset_condition)
reset = 1
elsewhen edge(reset) % Immediately put reset back to 0
reset = 0;
end
end
end
equations
if reset % Triggers only for one moment
x == IC
else
y == I
end
x.der == y;
end
end
equations
O == x;
end
annotations
x0 : UnitDropdown = common
end
end

I used smimport(xml file) from solidwork and add PS Constant and PS Integrator to rotate wheel but error
回答 (0 件)
参考
カテゴリ
Help Center および File Exchange で Simscape Multibody についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!