フィルターのクリア

Error:Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the following blocks

481 ビュー (過去 30 日間)
I had connected a solver configuration block in my model but these error is popping up when i connect a "current-Voltage simscape interface" block in my model.Kindly guide me in solving this problem. Thanking you, Saideep.

回答 (4 件)

Yogeshwar Bala
Yogeshwar Bala 2018 年 10 月 6 日
Connect an "Electrical Reference" block to your ground line and add a Solver Configuration block with default value of f(x) = 0 to it.
  5 件のコメント
Reginald Ogu
Reginald Ogu 2023 年 3 月 17 日
Please how can I add a Solver Configuration block to my Simscape model?
Huang YanMing
Huang YanMing 2024 年 3 月 4 日
To add a "Solver Configuration"
Go to library browser and find it in the below folder
Simscape>Utilities

サインインしてコメントする。


Behnam Mohammad
Behnam Mohammad 2020 年 1 月 15 日
What happens when you have multiple subsystems and each subsystem has an individual solver?

ever steeven nevarez cedeño
ever steeven nevarez cedeño 2021 年 8 月 31 日
tengo un problema similar pero al reves el problema es cuando lo pongo

Joel Van Sickel
Joel Van Sickel 2024 年 6 月 10 日
This specific problem happens from the interface block. Those blocks are used to decouple simscape networks and if you look under the hood, you will see they are connected by simulink wires, not simscape wires. This means that if you use one, you will now have an additional simscape network, so you will need to add an additional simscape configuration block to the side of the network that doesn't already have one. Or you will need to add it to both sides if neither side has one.