Hi, I am new to simulink.when i observe the signal genrator output in a scope ,i see that the signal appears only for 10 units. I tried using a sine wave as input and still the output in scope appears only for 10 units..i want the signal to appear for more than 10 units.. what settings should i change so as to observe the signal for more time duration..please help me.. thank you..

採用された回答

Abhiram Bhanuprakash
Abhiram Bhanuprakash 2014 年 10 月 30 日
編集済み: Abhiram Bhanuprakash 2014 年 10 月 30 日
Hi Amrutha,
I think the issue is occurring because you have limited the scope display data points to the last x samples (where x is the number of samples in 10 units).
To change this, double-click on the scope in the model, go to Parameters (gear-shaped icon) -> History tab -> Uncheck the 'Limit data points to last' option, or change it to limit the data points to whatever you want.
Hope this helps,
Cheers!
Abhiram.