cameraIntrinsicsFromOpenCV does not seem to account for differences in distortion model
5 ビュー (過去 30 日間)
古いコメントを表示
Min seok Kang
2021 年 11 月 10 日
コメント済み: Min seok Kang
2021 年 11 月 10 日
The function cameraIntrinsicsFromOpenCV in the Computer Vision toolbox seems to give out wrong distortion coefficients.
And thus, the results of MATLAB's undistort functions do not seem to be right when using the camera intrinsics from OpenCV. Is there a way to undistort points manually?
0 件のコメント
採用された回答
Giridharan Kumaravelu
2021 年 11 月 10 日
The two equations mentioned in your question are essentially the same if the higher order radial distortion coefficients (k4-k6) in OpenCV are set to zero.
By default, OpenCV's calibration tools like cv.calibrateCamera calibrate for two radial distortion coefficients (k1 and k2) only. Often times, this is sufficient to model normal lenses.
Unless you have explicitly calibrated for more than 3 radial coefficients in OpenCV, you should be able to accurately import those camera parameters from OpenCV using cameraIntrinsicsFromOpenCV.
3 件のコメント
Giridharan Kumaravelu
2021 年 11 月 10 日
Unfortunately, CVT camera calibration tools currently do not support using more than 3 radial distortion coefficients. Isn't there a way to limit the number of radial distortion coefficients in the Azure Kinect SDK? If not, could you directly calibrate the camera using CVT's Camera Calibrator app or using the estimateCameraParameters function?
その他の回答 (0 件)