Slow simulation with noisy output

Hi,
i have this issue with slow simulation time for a stable first order tranfers function.
I've tested it with and without the Dead zone and I get the same results. The Scope1 show a intense oscillation of the output.
Thanks
Alexandre

1 件のコメント

Aniruddha Katre
Aniruddha Katre 2014 年 9 月 3 日
This behavior stems from the fact that the time-step taken by the solver is so large that it fails to capture the dynamics of the system, which has a bandwidth of 200000 rad/s.
Consistent with the Nyquist sampling theorem, if you run the simulation using a fixed-step solver with step size of around 1/400000, then you will not observe this kind of oscillation.

回答 (0 件)

この質問は閉じられています。

質問済み:

2014 年 9 月 3 日

閉鎖済み:

2021 年 8 月 20 日

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by