Hi
How do I convert a Fixed-in-Minor-Step sample time signal to a Continuous sample time signal without changing solvers?
  1 件のコメント
dzid_
dzid_ 2019 年 6 月 11 日
Yeah, how? What is the trick?
I have multiplied the FiM signal by a Continuous signal (equal=1) and it made it it continuous but that's dirty solution

サインインしてコメントする。

回答 (1 件)

Archit Dhanani
Archit Dhanani 2019 年 7 月 19 日
There is a shipped SFunction 'sfun_d2c' which you could try using. It provides algorithms that essentially performs a linear extrapolation on the sampled data.
You can find an example using this S-Function at the following location in the MATLAB installation:
matlab\toolbox\simulink\simdemos\simfeatures\sfcndemo_d2c
You can use the command:
>>cd(matlabroot);
>>cd toolbox\simulink\simdemos\simfeatures
>>sfundemo_d2c
See if this helps avoiding the issue.