I am trying to simulate a three phase grid connected inverter with LCL filter as shown in picture. I am trying to complete the simulation in open loop condition first before going to close loop with DQ transformation. I am using a 2-level PWM generator to provide gate signals. The simulation is done in two steps
Step 1, Only load connected and Three Phase source(grid) commented out. The output is fairly good sinuosoidal as expected. V=400V, I=20A
Step 2, Grid is connected and simulation is run. The output is not how I wanted. Voltage waveform is pretty ok. But current waveform have higher magnitude and higher harmonics.
My question is what could be the reason for higher currents when inverter is grid connected and what could be the reason of such non sinuosiodal current waveform. Can anyone help me with getting this problem fixed or share their three phase grid connected model?
0 件のコメント
回答 (2 件)
Joel Van Sickel
2021 年 8 月 25 日
Hello Akhtar,
running open loop on a grid connected simulation would often not work since it won't by synchronized with the grid. It is possible in simulation but you'd need to often tweak a number of phase ofsets and frequencies to ensure it actually worked, which is probably more work than just synchronizing it to the gril with PLL and closed loop controller given the examples that are available. There are shipping examples of how this works grid connected:
Regards,
Joel
SOURABH GHOSH
2021 年 8 月 26 日
There exists a simulink model example: 250-kW Grid-Connected PV Array - MATLAB & Simulink - MathWorks India
You can derive some ideas from this example.