Default Deactivation of "Limit data points to last" in Simulink Viewer

6 ビュー (過去 30 日間)
Martin
Martin 2013 年 11 月 25 日
回答済み: Zack Peters 2013 年 11 月 25 日
If you add a viewer to a line, the data point limitation is activated by default with a value of 7500. Is it possible to deactivate this limitation for all new viewers? Can this be done as a default setting only on model level or as general default setting?

採用された回答

Zack Peters
Zack Peters 2013 年 11 月 25 日
Hi Martin,
Currently there is no way to set this on a model level or at the Simulink preferences level. One thing you may try is to create a Scope library block and change the setting in there. From there you can open that library and drop that block (and not the default simulink scope) into new models.
~Zack