Model advisor and variant subsystems

9 ビュー (過去 30 日間)
Rajesh
Rajesh 2013 年 11 月 12 日
回答済み: Poulami Ghosh 2021 年 9 月 30 日
Hi,
I am using model advisor to check unconnected lines and ports in a model. I have some subsystems that have variant subsystems in the model.Inside the active variant model,I have a unconnected line.
But after running the check in model advisor,the report doesn’t show the unconnected line that was inside active variant subsystem.
I am using R2011b.Could you please let me know why?
Thanks for the answer.
Regards,
Rajeshkumar.

回答 (1 件)

Poulami Ghosh
Poulami Ghosh 2021 年 9 月 30 日
As per my understanding, the model has Variant subsystem and the active choice of the Variant subsystem has some unconnected lines. When the model advisor check- ‘Identify unconnected lines, input ports, and output ports’ (check ID: mathworks.design.UnconnectedLinesPorts) is run, the check should have reported the issue. But the model advisor check did not report it.
I tried to reproduce the issue till R2014a and could see model advisor reporting the warning.
Given this, it seems like this stand fixed as of R2014a.