Can I generate data visualizations like heatmaps on matlabs' site viewer?
Try the propagationData function. Using propagationData and its contour function, you can load custom data into the data object ...
4年以上 前 | 1
how to save siteviewer image from coverage function
Based on your responses, it looks like you want to save a snapshot of the Site Viewer window, similar to saving a figure window'...
6年弱 前 | 0
| 採用済み
Online exchange of data between Matlab and MEX-file/thread
1. The updating of line data + drawnow is the best way to go about updating the plot. However, instead of using "while(1)", yo...
7年以上 前 | 0
Reset Constant value in Simulink from Matlab GUI
This is a very common issue, and I completely understand why! The issue here is because in line 81 of "change_const.m", the v...
7年以上 前 | 1
| 採用済み
How to set define a header files directory for the MinGw64 compiler
Rather than changing the C++ code to have the path to the header, you can call "mex" with the "-Ipathname" flag to specify the p...
7年以上 前 | 0
How to generate Optimization toolbox functions(like fmincon )code for Raspberrypi ?
Unfortunately, code cannot be generated for many functions in the optimization toolbox, like "fmincon". For the full list of fun...
7年以上 前 | 0
| 採用済み
Simscape Fix-step simulaiton with two different time steps
According to the following doc page: <https://www.mathworks.com/help/simulink/ug/saving-and-restoring-the-simulation-state-as-t...
7年以上 前 | 0
Wavelet question about the timing of coefficients compared to original signal
Since the original plot has a scale of 1:4000, the first detail coefficient d1 must have a size of 1:2000. This is because calcu...
7年以上 前 | 0
| 採用済み
How can i delete error of variable-size on Simulink?
The "Error Rate Calculation" block does not support variable-sized signals, as confirmed by this documentation link: <https:/...
7年以上 前 | 0
| 採用済み
Why does the high-side switch turn ON with the Buck converter in the figure below?
It looks like the ideal semiconductor block is intended to be in the "on" state when the gate-cathode voltage exceeds the thresh...
7年以上 前 | 0
| 採用済み
How to fix "Failed to generate all binary outputs"
It looks like the spaces in your file path are causing the issue. MATLAB and Simulink typically have issues with spaces in the f...
7年以上 前 | 1
How do I change my trigger commands for a session based interface in the Data Acquisition Toolbox?
You're probably already using the following link to transition your code to session-based, but just in case, this link is very h...
7年以上 前 | 0
| 採用済み
Why does robstab return stable perturbation?
I agree that the values do not seem correct. In fact, strangely if you use the range [0.55, 1.5] with a nominal value of 1, then...
7年以上 前 | 0
| 採用済み
Compare Correlation Coefficients with multiple comparisons?
You could calculate the p value using the function you linked, and then perhaps try using the following function on the file exc...
7年以上 前 | 0
| 採用済み
Boxplot with 5th and 95th percentile with multiple data sets
You could use the "whisker" parameter in the "boxplot" function. i.e boxplot(data, group,... 'symbol','','factordirection',...
7年以上 前 | 0
ERT control Row major matrix order
Unfortunately, due to the way both languages are implemented, changing the matrix order convention is not possible in the genera...
7年以上 前 | 0
| 採用済み
how to solve multiple iteration for multiple input?
You could create another for loop outside your "while" loop that changes epsilon during each iteration. Then you substitute this...
7年以上 前 | 0
| 採用済み
USRP B210 GPSDO time?
Unfortunately, the ability to get the timestamps of each sample is not currently possible in Simulink. I have notified the ...
7年以上 前 | 0
Selecting only the top half of values from a text document?
Is each line of the data one entry in the table? That is, are you taking the top half of lines to be put into one column, and th...
7年以上 前 | 0
| 採用済み
how to perform Signal amplitude demodulation
Using any kind of lowpass filter in general should introduce some delay, so the results you are seeing are to be expected. That ...
7年以上 前 | 0
RS232 issue under Simulink realtime
Since the function has an inherited sampling time (-1), the rate at which it is executed is dependent on the block that feeds in...
7年以上 前 | 0
Is there a way I can impose Constraints on the model parameters while working with greybox modeling (greyest)?
Unfortunately this seems to be a limitation in the "greyest" function. It is currently not possible to give a boundary to "greye...
7年以上 前 | 0
AnalysisPoint fails when using multiple connect commands
This is actually a limitation of the "connect" function. I have notified the developers of this. For now, the error points t...
7年以上 前 | 1
| 採用済み
How can I stop C MEX s-function from outputting anything?
It shouldn't be possible to remove the output entirely, since if there is an outport on your s-function block, there will always...
7年以上 前 | 0
How can I reset/change ciruit ports?
Unfortunately, modifying/resetting the ports on a defined circuit object is currently not possible. Once a circuit object is cre...
7年以上 前 | 1
| 採用済み
options for genetic algorithm with sdo.optimize
Since you are using @searchga as the search function for sdo.optimize, perhaps you could try to pass in additional information a...
7年以上 前 | 0
| 採用済み
Inverse Z-transform mismatch
The above difference is because the z transform is only valid for non-negative integers. In fact, if you plot the two functions ...
7年以上 前 | 0
3/2 pneumatic valve model
It sounds like you're building this component using a series of other components (like the variable restriction component, and o...
7年以上 前 | 0
What is SetSimViewingDevice?
Unfortunately, the serial send/receive blocks from the Instrument control toolbox are not supported for code generation. Therefo...
7年以上 前 | 1
| 採用済み
Include timeseries data from workspace in Simulink and activate them by trigger during simulation
In general, timeseries data must go hand-in-hand with the current time of the simulation. So unfortunately, having the data eval...
7年以上 前 | 0