Ralph Youngs
BMT Syntek Technologies
Followers: 0 Following: 0
Professional Interests: Power Systems
Feeds
質問
What is the correct angular velocity in Simscape electrical demo "Synchronous Machine Initialization with Loadflow"?
Data explorer reports the angular velocity at 60Hz as 37.6 rad/s not 60*2*pi (377). see example ee_loadflow_sm_initializatio...
3年弱 前 | 1 件の回答 | 0
1
回答回答済み
Why is my signal builder not giving precise outputs?
Try increasing the Decimation and especially the Refine factor. I've needed a refine factor of 10 to recover ms precision in ti...
Why is my signal builder not giving precise outputs?
Try increasing the Decimation and especially the Refine factor. I've needed a refine factor of 10 to recover ms precision in ti...
5年弱 前 | 0
質問
Three-Phase Transformer (Two Windings)
There is an error in the winding's per unit parameter for Leakage Reactance. The mask documentation calls for Leakage Inductanc...
10年以上 前 | 1 件の回答 | 0