Feeds
回答済み
How to create this in Simulink? std_logic_vector16 vec[0:3]
Hello Cheri, If you're generating HDL code from a Simulink subsystem using makehdl, the behavior you're describing is already s...
How to create this in Simulink? std_logic_vector16 vec[0:3]
Hello Cheri, If you're generating HDL code from a Simulink subsystem using makehdl, the behavior you're describing is already s...
7ヶ月 前 | 1
| 採用済み
回答済み
Specify clock pins in HDL Reference Design
Hi John, The addClockInterface API in HDL Coder requires you to specify a connection point in your design. For instance, if you...
Specify clock pins in HDL Reference Design
Hi John, The addClockInterface API in HDL Coder requires you to specify a connection point in your design. For instance, if you...
11ヶ月 前 | 1
| 採用済み
回答済み
simulink ip core generation
Hello, To use the AXI4-Stream interface in the IP core generation workflow in HDL Coder, you can model your algorithm to operat...
simulink ip core generation
Hello, To use the AXI4-Stream interface in the IP core generation workflow in HDL Coder, you can model your algorithm to operat...
1年以上 前 | 0
回答済み
AXI-stream interface violates AXI-stream protocol
Hello Alexander, I'd like to provide some clarity on the protocol implementation within our IP core generation workflow. When m...
AXI-stream interface violates AXI-stream protocol
Hello Alexander, I'd like to provide some clarity on the protocol implementation within our IP core generation workflow. When m...
2年弱 前 | 0
回答済み
Setting Target interface fails in Debug Zynq design using HDL and Embedded coder example.
Hello Vishnu, The error message you're seeing typically appears when a reference design requires certain non-optional interfac...
Setting Target interface fails in Debug Zynq design using HDL and Embedded coder example.
Hello Vishnu, The error message you're seeing typically appears when a reference design requires certain non-optional interfac...
約2年 前 | 1
回答済み
HDL Workflow Advisor - Step 3.2 - "Failed Index exceeds the number of array elements. Index must not exceed 2" in hdlturnkey.interface.ChannelBased/connectFrameInterfacePort
Hello, From your description it sounds like you are using the "legacy frame-based modeling" detailed in: https://www.mathwor...
HDL Workflow Advisor - Step 3.2 - "Failed Index exceeds the number of array elements. Index must not exceed 2" in hdlturnkey.interface.ChannelBased/connectFrameInterfacePort
Hello, From your description it sounds like you are using the "legacy frame-based modeling" detailed in: https://www.mathwor...
2年以上 前 | 0
| 採用済み