How to speed up simscape electrical simulation?
Dear Hassan Ali, I had a look at your model and I can notice that margins of improvements are in the direction of model fide...
How to speed up simscape electrical simulation?
Dear Hassan Ali, I had a look at your model and I can notice that margins of improvements are in the direction of model fide...
5日 前 | 0
| 採用済み
回答済み
How to Select Components for Circuit Design in MATLAB Given Limited Library Options?
Hi Naveen Sai, The Simulink library blockset is strictly speaking not specialized for physical modeling in the electrical domai...
How to Select Components for Circuit Design in MATLAB Given Limited Library Options?
Hi Naveen Sai, The Simulink library blockset is strictly speaking not specialized for physical modeling in the electrical domai...
9日 前 | 0
回答済み
I am unbale to connect three phasr VSI inverter model with my MUX input, because they are from different library. How can i coneect ?
Hi Snehil, You cannot connect Physical Conserving ports shaped as squares to Simulink signals shaped as arrow heads. To learn...
I am unbale to connect three phasr VSI inverter model with my MUX input, because they are from different library. How can i coneect ?
Hi Snehil, You cannot connect Physical Conserving ports shaped as squares to Simulink signals shaped as arrow heads. To learn...
24日 前 | 0
回答済み
Where Can I Download the PID Controller Tuning for a Buck Converter Example?
Hi, If you are looking for more recent content, please have a look at the following links: Technical article (no files, but co...
Where Can I Download the PID Controller Tuning for a Buck Converter Example?
Hi, If you are looking for more recent content, please have a look at the following links: Technical article (no files, but co...
3ヶ月 前 | 0
回答済み
Can we change parameters inside 'block parameters' of Ideal IGBT block?
Hi, A little head-up on your task. I see that you are calculating the efficiency by using Simulink blocks. Even though theore...
Can we change parameters inside 'block parameters' of Ideal IGBT block?
Hi, A little head-up on your task. I see that you are calculating the efficiency by using Simulink blocks. Even though theore...
9ヶ月 前 | 1
回答済み
why is it impossible to use the PID tuning app when tuning a PID controller used in circuits that have PWM switchings?
Dea Hassan, The failure in the linearization process is normal due to the discontinuities associated to switching events. This...
why is it impossible to use the PID tuning app when tuning a PID controller used in circuits that have PWM switchings?
Dea Hassan, The failure in the linearization process is normal due to the discontinuities associated to switching events. This...
2年以上 前 | 0
回答済み
Why is the settling value of my TF so high when compared to my output value? How can I resolve this?
Dear Samuel, the discrepancy you're getting may be explained by the presence of other nonidealities you model with Simscape Elec...
Why is the settling value of my TF so high when compared to my output value? How can I resolve this?
Dear Samuel, the discrepancy you're getting may be explained by the presence of other nonidealities you model with Simscape Elec...
2年以上 前 | 0
回答済み
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
Dear Samuel, The difficulties you are encountering are understandable since when you tune a specific gain of your PID controlle...
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
Dear Samuel, The difficulties you are encountering are understandable since when you tune a specific gain of your PID controlle...
2年以上 前 | 0
回答済み
In "frestimate(modelname,op,io,in)", it is required for each of the linearization input I/O points that the sample time of the Simulink signal where it is located is one of the following:
Hi, both input linearization point and output measurement point are required to be equally sampled and must match the perturbati...
In "frestimate(modelname,op,io,in)", it is required for each of the linearization input I/O points that the sample time of the Simulink signal where it is located is one of the following:
Hi, both input linearization point and output measurement point are required to be equally sampled and must match the perturbati...
4年弱 前 | 3
| 採用済み