Why is the output of the Simulink 'Bitwise Operator' a matrix (CompiledPortDimension)
古いコメントを表示
Why is the output of the Simulink 'Bitwise Operator' a matrix (CompiledPortDimension)?
Which other blocks behave the same way?
2 件のコメント
Kaustubha Govind
2013 年 6 月 12 日
What are the dimensions of the input(s) to the block in your model?
Ernst
2013 年 6 月 13 日
回答 (1 件)
Kaustubha Govind
2013 年 6 月 13 日
0 投票
It looks like the 'Bit Mask' parameter on the block may be a non-scalar in your block, which is why the output is a matrix even when the input is scalar.
2 件のコメント
Ernst
2013 年 8 月 8 日
Kaustubha Govind
2013 年 8 月 8 日
Ah! I think you may not be interpreting the CompiledPortDimension correctly - from my understanding, the first digit represent the number of dimensions, and the following digits represent the length of each dimension. So essentially, your output is a signal with dimensions 1x1 (ie. 2D signal). Does that make sense? For example, if the output were a mxnxp signal, CompiledPortDimension would be [3 m n p].