Cooley-Tukey FFT: You don't have to zeropad to a power of 2?
3 ビュー (過去 30 日間)
古いコメントを表示
Someone wrote "The algorithm that Cooley and Tukey presented in their classic paper (Math. Comp. 19 (1965), 297-301. http://dx.doi.org/10.1090/S0025-5718-1965-0178586-1) can be applied to any composite length. The performance advantages are greatest for highly composite lengths, of which powers-of-2 are one example, and lengths of powers-of-2 result in other advantages on binary computers, so *it has become a common misconception that the algorithm is only applicable to signals whose length is a power of 2*."
Does that mean that when you *DO use the Cooley-Tukey FFT* You don't have to zeropad to a power of 2? Take for example an image of 1920x1080. So, if you want to use the Cooley-Tukey FFT, you don't need to zeropad the 1920x1080 image to 2048*2048?
0 件のコメント
回答 (2 件)
Walter Roberson
2013 年 6 月 2 日
Correct. Do not pad to a power of 2 when using that algorithm.
Note: The MATLAB fft() and fft2() calls do not require padding to powers of 2.
6 件のコメント
Malcolm Lidierth
2013 年 6 月 5 日
Can you really do 0.4918530963 complex multiplications? Perhaps with Wisdom=Norman!
参考
カテゴリ
Help Center および File Exchange で Fourier Analysis and Filtering についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!