Simulink :: Change the number of continous-states during simulation
古いコメントを表示
Is it possible to change the number of continous-states during simulation?
In Level-2 S-function
and how?
回答 (2 件)
Kaustubha Govind
2013 年 5 月 8 日
0 投票
No, the number of states (continuous/discrete) needs to be configured in the setup method, and cannot change during simulation.
Bakró
2013 年 5 月 8 日
0 投票
1 件のコメント
Kaustubha Govind
2013 年 5 月 9 日
Yes, it is. You can read the dialog parameter value in the setup method. (Also, as an aside, could you ask follow-up questions as a comment to my original answer. It is confusing to ask a question as an "Answer". Thanks!)